WEBVTT 00:03.740 --> 00:06.190 This is a video walk through of Bat Doc , 00:06.200 --> 00:08.860 highly customizable Android application 00:08.860 --> 00:10.860 developed by the Air Force Research 00:10.860 --> 00:13.082 Laboratory , Toe wirelessly Monitor and 00:13.082 --> 00:16.710 document Multiple Patients Care . Bat 00:16.710 --> 00:18.877 Doc provides a wealth of functionality 00:18.877 --> 00:20.710 that can be broken down into six 00:20.710 --> 00:22.850 categories . Those categories . Our 00:22.850 --> 00:24.630 assessment of patient care , 00:24.640 --> 00:27.020 documentation of patient care , 00:27.030 --> 00:29.640 collaboration between medical providers , 00:29.650 --> 00:31.620 medical reference material , 00:31.630 --> 00:35.050 coordination of evacuation and transfer 00:35.050 --> 00:38.930 of patients and their data . The 00:38.930 --> 00:41.480 first , subcategory assessment is built 00:41.480 --> 00:43.630 around Bath Ox ability to connect to 00:43.630 --> 00:45.940 third party FDA approved vitals 00:45.940 --> 00:48.340 monitoring devices . After adding a 00:48.340 --> 00:50.396 patient to the home screen , Bat Doc 00:50.396 --> 00:52.396 has incorporated multiple different 00:52.396 --> 00:54.562 ways to quickly and seamlessly pair to 00:54.562 --> 00:56.820 send pair sensors to the device . 00:58.740 --> 01:01.380 The first way is to scan a QR code on 01:01.380 --> 01:02.660 the back of a sensor , 01:07.940 --> 01:09.940 and momentarily , vitals will start 01:09.940 --> 01:12.051 streaming for that patient . Bad talk 01:12.051 --> 01:14.550 has also integrated NFC tags , allowing 01:14.550 --> 01:17.380 the user to simply touch the sensor to 01:17.380 --> 01:20.450 the phone , select the patient . They 01:20.450 --> 01:23.320 want those vitals to stream for a 01:23.320 --> 01:25.098 momentarily . Vitals will start 01:25.098 --> 01:27.153 streaming for that patient as well . 01:27.740 --> 01:29.840 Bat Doc can handle multiple patients 01:29.850 --> 01:31.794 and gives providers the ability to 01:31.794 --> 01:35.350 assign triage color to those patients 01:35.360 --> 01:37.450 and automatically sorts to allow 01:37.450 --> 01:39.672 providers to focus on the most critical 01:39.672 --> 01:42.390 patients . Providers can also set 01:42.390 --> 01:44.550 thresholds for individual patients 01:46.740 --> 01:49.410 to get alerted if the patient falls 01:49.410 --> 01:52.530 outside a desired level , further 01:52.540 --> 01:54.540 allowing them to focus on immediate 01:54.540 --> 01:57.990 patient care tasks . Assessment is 01:57.990 --> 02:00.046 additionally supported by displaying 02:00.046 --> 02:02.770 vitals over time so that medics concede 02:02.770 --> 02:04.548 the effective interventions and 02:04.548 --> 02:06.714 treatments in their patients health as 02:06.714 --> 02:08.548 well as quickly determine if the 02:08.548 --> 02:10.714 patients are trending in a positive or 02:10.714 --> 02:12.826 negative direction . Smartwatches Air 02:12.826 --> 02:15.280 also integrated to show patient vitals 02:15.280 --> 02:17.540 and hands free form factor that allows 02:17.540 --> 02:19.707 providers to focus on care while still 02:19.707 --> 02:21.596 receiving alerts If patients fall 02:21.596 --> 02:23.596 outside of pre defined thresholds , 02:25.640 --> 02:28.350 documentation of patient care is 02:28.350 --> 02:31.080 accomplished By selecting a patient and 02:31.080 --> 02:32.636 jumping directly into their 02:32.636 --> 02:34.636 documentation , you're able to mark 02:34.636 --> 02:38.440 locations of mechanisms of injury . You 02:38.440 --> 02:41.700 can do freeform drawings to show larger 02:41.700 --> 02:42.550 areas , 02:45.740 --> 02:49.180 placing tourniquet . It's and then 02:49.180 --> 02:51.180 jumping directly into the signs and 02:51.180 --> 02:53.347 symptoms tab . This tab allows a medic 02:53.347 --> 02:56.140 two semi autonomously place patient 02:56.140 --> 02:58.760 vitals onto their documentation forms . 02:59.640 --> 03:01.529 It pulls vitals directly from the 03:01.529 --> 03:03.696 connected wireless sensors , which can 03:03.696 --> 03:05.150 be edited as needed . 03:07.540 --> 03:10.410 It also has the ability to add vitals 03:10.420 --> 03:13.090 in a given time interval , as required 03:13.100 --> 03:15.760 by the patient's level of criticality 03:23.940 --> 03:26.270 treatments , are simple . Guess Cher's 03:26.280 --> 03:28.860 touching the buttons medicines Air 03:28.860 --> 03:31.530 added very simply , with a easy to find 03:31.540 --> 03:35.120 dialogue that can handle whatever 03:35.130 --> 03:37.260 meds are in the medics bag . 03:40.540 --> 03:42.780 Bad talk is also integrated . NFC is 03:42.780 --> 03:45.140 with its medicines to allow users to 03:45.140 --> 03:48.490 put an NFC define what the medicine is 03:48.500 --> 03:51.040 and thereby just touching the med to 03:51.040 --> 03:53.570 the back of the phone and giving 03:53.570 --> 03:56.050 accurate time stamp and medicine type . 03:57.060 --> 03:59.470 They can later go in and add the routes 03:59.480 --> 04:02.930 and dosages , but the time stamp stays 04:02.930 --> 04:06.690 consistent . The events 04:06.690 --> 04:09.730 tab allows for the user to see exactly 04:09.730 --> 04:11.952 what happened at what time it is a time 04:11.952 --> 04:14.230 history of all the care that has been 04:14.230 --> 04:17.090 given to the patient times could be 04:17.090 --> 04:19.600 edited , and the list immediately racks 04:19.600 --> 04:21.044 and stacks those events . 04:23.040 --> 04:25.096 Documentation is further enhanced by 04:25.096 --> 04:27.410 giving medics the ability to take 04:27.420 --> 04:31.230 images and saving those images In the 04:31.230 --> 04:34.710 patient's archive . Collaboration is 04:34.710 --> 04:36.960 accomplished by networking multiple bat 04:36.960 --> 04:38.960 doc systems together either through 04:38.960 --> 04:41.360 team networks , WiFi or Bluetooth 04:43.040 --> 04:45.270 bat doc synchronizes , all patients 04:45.270 --> 04:47.437 being treated and all their associated 04:47.437 --> 04:49.659 documentation . This allows for care to 04:49.659 --> 04:51.970 be started by one provider and 04:51.970 --> 04:54.192 seamlessly continued , bought all other 04:54.192 --> 04:55.692 providers on the network . 04:56.440 --> 04:58.860 Documentation by one medic displays 04:58.860 --> 05:01.560 real time on all other bad doc systems . 05:12.240 --> 05:14.750 Bad Doc also contains a large amount of 05:14.760 --> 05:17.680 medical reference material saved in the 05:17.680 --> 05:20.030 med cards . This allows medics to 05:20.030 --> 05:23.360 quickly remember protocols and 05:23.360 --> 05:25.650 overviews of different types of care 05:25.660 --> 05:28.040 without having to look in their 05:28.050 --> 05:31.350 handbooks . This is a user to findable 05:31.350 --> 05:34.110 list any PdF or word document or images 05:34.110 --> 05:37.580 can be saved for quick access . It also 05:37.580 --> 05:40.250 has interactive calculators . 05:45.230 --> 05:48.140 There isn't increased number of medical 05:48.140 --> 05:50.680 documentation that could be added and 05:50.680 --> 05:53.330 attached to specific patients from the 05:53.330 --> 05:54.663 medical cards as well . 05:59.440 --> 06:01.410 Team coordination is accomplished 06:01.410 --> 06:03.890 through a team lead module that allows 06:03.890 --> 06:06.390 medics to plan the evacuation of 06:06.390 --> 06:09.410 patients onto which platforms they will 06:09.410 --> 06:12.680 be on and sends a message to all other 06:12.880 --> 06:15.810 medics on the network of which patients 06:15.820 --> 06:19.360 are outbound . The final step of 06:19.360 --> 06:21.249 patient care is the transfer of a 06:21.249 --> 06:23.249 patient's documentation to the next 06:23.249 --> 06:25.920 level of care . Bat Doc displays a 06:25.930 --> 06:28.260 quick handoff view that gives a brief 06:28.270 --> 06:31.090 overview of all the patient care that 06:31.090 --> 06:34.030 had been done up to this point . It 06:34.030 --> 06:36.140 helps medics quickly and accurately 06:36.140 --> 06:38.418 communicate when handing off a patient . 06:39.440 --> 06:42.880 Q R codes have been utilized to encode 06:42.880 --> 06:45.350 patient documentation for air gap 06:45.350 --> 06:48.450 between devices and be able to pass off 06:48.450 --> 06:49.550 that information . 06:58.610 --> 07:01.040 NFC tags can also be used to write 07:01.040 --> 07:04.980 patient documentation and be read 07:04.980 --> 07:08.930 into another device when a 07:08.930 --> 07:11.570 paper copy is needed . Bat Doc has 07:11.570 --> 07:13.630 integrated Bluetooth printers that 07:13.630 --> 07:15.963 simply touch your device to the printer . 07:16.640 --> 07:19.060 Bat dog does all the pairing needed 07:27.640 --> 07:31.120 after selecting print . A hard copy is 07:31.120 --> 07:34.050 printed on the Bluetooth printer . Okay , 07:40.340 --> 07:43.980 yeah , a windows , as well as Iowa's 07:45.740 --> 07:48.220 applications , have been created to 07:48.220 --> 07:50.360 scan patient documentation .